The VCF6 are pressure compensated flow control valves. A typical example of application is the return line of a hydraulic cylinder. Their function is to guarantee the lowering at constant speed even in the presence of load variations. The VCF6 are adjustable valves, via the adjustment screw it is possible to vary the outlet flow form the valve. By means of the nut positioned on the adjustment screw, the setting of the valve is protected against accidental tampering. In this case, for an optimal functioning of the valve it is recommended to always guarantee an inlet flow of at least 10% higher than that to be regulated. The VCF6 valve manages the constant flow in a single direction through the valve itself; in the opposite direction there is no hydraulic compensation and the flow through the valve is free with pressure drops proportional to the flow rate and to the passage area. The maximum working pressure for the VCF6 valve is 350 bar. The VCF6 flow control valves can be installed in 2-way cavities dimensioned according to the SAE08 standard (3/4-16 UNF thread). In addition to the screw adjustment (standard), the VCF6 is also available with a handwheel regulation (sold separately). All the valve components are made of high-strength steel and the external components are protected from the action of corrosive agents by zinc-plating treatment.
Cartridge Cavity = SAE08-2
| Part # | Cavity | Controlled Flow Min | Controlled Flow Max | Max Pressure |
|---|---|---|---|---|
| VCF63C | SAE8-2 | 1.3 lpm | 5.1 lpm | 350 bar |
| VCF65C | SAE8-2 | 2.6 lpm | 9.1 lpm | 350 bar |
| VCF67C | SAE8-2 | 4 lpm | 14.4 lpm | 350 bar |
Hand knob adjustment also available (Part #12000354)
WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.