VRPEDAD Series pressure reducing valve, manufactured in Italy by OFC Villa Hydraulics.
Pressure reducing valves reduce a high primary pressure at the inlet (port V) to a constant reduced pressure at port C. Tank port (T) must be connected to a return to tank line. Full reverse flow from reduced pressure (port C) to inlet (port V) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
Note: This valve has no relieving capability. It should not be used in a dead-headed application. If the reduced pressure side of the circuit has very low leakage the pressure may rise significantly. The pressure rise will vary from valve to valve.
| Part # | Ports | Max Flow | Max Pressure | Max Pressure Range | Material |
|---|---|---|---|---|---|
| VPREDAD02 | 3/8” BSPP | 30 lpm | 250 bar | 140 bar | Aluminium |
WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.