Oleoweb VUR check valves are widely used in all hydraulic applications, from the mobile to the industrial sector. The VUR-BSPP are unidirectional valves for in-line installation. The shutter, poppet or ball, is housed inside a body with female threads, available in sizes 1/8″ BSPP to 2″ BSPP. The oil flow is free from port 2 to port 1 while it is interrupted by port 1 to port 2. The standard opening pressure of the shutter is fixed at 0.5 BAR; different opening pressures are available on request. (3 BAR, 4.5 BAR & 6 BAR cracking pressure options available). The external body is made of high-strength steel and protected externally from corrosion by galvanizing treatment.
| Part # | Ports | Max Flow | Max Pressure | Pilot Ratio | Material |
|---|---|---|---|---|---|
| VUR180 | 1/8” BSPP | 5 lpm | 400 bar | 0.5 bar | Steel |
| VUR140 | 1/4” BSPP | 15 lpm | 400 bar | 0.5 bar | Steel |
| VUR380 | 3/8” BSPP | 30 lpm | 400 bar | 0.5 bar | Steel |
| VUR120 | 1/2” BSPP | 50 lpm | 400 bar | 0.5 bar | Steel |
| VUR340 | 3/4” BSPP | 90 lpm | 400 bar | 0.5 bar | Steel |
| VUR100 | 1” BSPP | 150 lpm | 350 bar | 0.5 bar | Steel |
| VUR114 | 1.1/4” BSPP | 200 lpm | 350 bar | 0.5 bar | Steel |
| VUR112 | 1.1/2” BSPP | 300 lpm | 350 bar | 0.5 bar | Steel |
| VUR200 | 2” BSPP | 430 lpm | 250 bar | 0.5 bar | Steel |
Variations and performance information can be found in the pictures.
WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.