Shop

Contamination Monitor – MP Filtri ICM 2.0

Original price was: $16,199.70$14,727.00.Current price is: $9,881.82$8,983.47. INC GSTEX GST

- +

The ICM 2.0 automatically measures and displays particulate contamination, moisture and temperature levels in various hydraulic fluids. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space and costs are limited. The ICM can be used as a standalone product or can be controlled by external PC, PLC or the ICM: RDU.

Features:

• Industry 4.0 ready live real time monitoring
• Calibrated to relevant ISO standards
• Manual, automatic and remote control flexibility
• Various communication protocols as standard
• FREE Windows based LPA View software. 8 channel contamination measurement &
display
• Measures and displays the following international standard formats; ISO 4406:1999,
NAS 1638, SAE AS 4059 revision E tables 1 & 2
• Moisture and temperature sensing (fluid dependent). Data logging and 4000 test result
memory
• Multicolor indicators via LCD (K versions) and LED with output alarm signals as standard
• Robust die cast aluminium construction
• Maximum operating pressure to 420 bar
• Environmental protection IP65/67 versatile
• Secondary connector to allow the simultaneous control/ download of results during
operation
• Option available to download directly all results onto a USB stick. RS485, MODBUS,
CANBUS, 4-20mA analogue output as standard

 

Technical Data

Particle sizing
>4, 6, 14, 21, 25, 38, 50, 70 μm(c) to ISO 4406:2017
Standard analysis range
ISO 4406:2017 Code 0 to 25
NAS 1638 Class 00 to 12
AS4059 Rev. E Table 1&2 Sizes A-F: 000 (Lower Limits are Test Time dependent)
Accuracy
± 1/2 code for 4,6,14 μm(c) ± 1 code for larger sizes
Viscosity
range ≤ 1000 cSt
Fluid temperature
From -25 °C to +80 °C
Ambient temperature
From -25 °C to +80 °C (non K version) From -25 °C to +55 °C (K version)
Temperature measurement
±3 °C
Pressure maximum
420 bar

 

 

WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.