This unit is a direct acting, screw in cartridge style, spool type, hydraulic directional logic element, with multi-functional potential when used with other directional pressure or flow control devices.
This valve is normally open from port 2 to port 1 with a spring bias. It will shift to allow full flow from port 2 to port 1 only when there is pressure in port 3. Valve will close when port 3 is opened and will maintain the same pressure plus the bias spring force value. When pressure is present at port 3, it will allow flow from port 3 to port 1, it will close once the pressure and the bias spring force is overcome by pressure in port 1. This is pilot to open directional control logic element.
| Part # | Cavity | Max Flow (LPM) | Max Pressure |
| LCEF-08-N-F-S-0-100 | 0825 | 30 | 350 bar |
| LCEF-10-N-F-S-0-160 | 1025 | 76 | 350 bar |
| LCEF-12-N-F-S-0-160 | 1225 | 136 | 350 bar |
WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.