This unit is a screw in, cartridge type, guided poppet, hydraulic pilot operated check valve, for use as a blocking or load holding device for high pressure applications.
POCI allows free flow from port 2 to port 1 and blocks flow from port 1 to port 2 or holding a load. Flow will be allowed from port 1 to port 2 when pressure is applied to port 3. This pilot operated check valve has a 3 to 1 pilot ratio, meaning that it takes at least one third of the load pressure held at port 1 that is required at port 3 to open the valve.
| Part # | Cavity | Max Flow (LPM) | Max Pressure |
| POCI-08-N-F-0-10 | 0825 | 37 | 350 bar |
| POCI-10-N-F-0-10 | 1025 | 70 | 350 bar |
| POCI-12-N-F-0-10 | 1225 | 132 | 350 bar |
WARNING – IMPROPER USE OR SELECTION OF THE PRODUCTS/EQUIPMENT OR SYSTEMS DESCRIBED CAN CAUSE PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. SAFETY PROCEDURES MUST BE APPLIED PRIOR TO INSTALLATION, COMMISIONING AND/OR OPERATION OF EQUIPMENT AND MACHINERY.